RSF-IIN_12-05Keep these instructions for future use.TheONYX APOwner's ManualResidential Factory Built FireplaceOperation • Maintenance • Inst
2. Frame an area to fit the Onyx AP. Follow the framing dimensions on (Figure 5). 3. Prepare the unit for installation. The holes in the side stand-of
CAUTION: When running ductaround corners, be sure to preventcrimping that would restrict thecombustion airflow. Use aninsulated duct rated at over 200
We recommend that the minimum height be increased by approximately 1 ft. for every 2000 ft. elevation abovesea level. Every 30° or 45° elbow also incr
MASONRYCHIMNEYWarning: When contemplating using an existing chimney, it must first be thoroughly inspected by an authorityhaving jurisdiction to deter
to the Excel chimney with the 3 screws provided. The stainless steel liner fits inside the clay liner all the way to thetop of the masonry chimney. It
NOTE: If the chase is enclosed or flashed to a roof as shown in (Figure 10), then the flashing must be vented.If required by local codes, make certain
BENEATH HEARTH EXTENSIONUnless raised 4” above the base of thehearth, the Onyx AP must use a 1/2” Durockciment board with a metal sheet (0.025”) or a3
ONYX AP OPTIONSJust a few comments about your Onyx AP options. The size and shape of your home and how you intend to useyour fireplace will determine
chain that is beside it. Let the chain down on the same side of the inner heat shield as the existing one andattach it to the lever on the damper moto
6. Slide the blower into place between the two brackets. You should be able to see the wheels of the blower.7. Mount the thermal switch on its support
SAFETY FIRST3 Do's and Don'ts3 CreosoteGENERAL SPECIFICATIONS4 Combustion Control System4 Ash Pan4 Thermostat Operation4 Internal Circulatin
you should add a synthetic latexadditive. Mix to a firm, moist con-sistency.4. Using a plasterer or mason'strowel, apply a scratch coat thatcover
(Figure 23) indicates the mini-mum clearances and framingdimensions. Passing through acombustible wall or ceilingrequires a minimum 13" x 13"
3) Part FDHB6: a maximum 636 C.F.M. blower with a variable speed motor, 2 noise reduction collars, a blowerspeed control and a mounting bracket and a
space and minimize cost. Maximum duct length should not exceed 50 feet from the fireplace to the furthest outlet.There is a loss of about 15% performa
area of the distribution system must total at least 50 square inches. If you have more than 50 square inches, someof the system may be shut off, but t
9. Wire the blower to a 115-volt, 15-amp breaker through the thermostat provided. The variable speed switch pro-vided should be installed in a conveni
11. If the blower still fails to operate, consult your localRSF Woodburning Fireplaces authorized dealer forrepair or replacement instructions.ZONE H
6. Follow the instructions supplied with your gas log set concerning the installation of gas lines, shut-off valves,etc. If you have the sand pan type
24VTransformerFigure 35: Wiring for the thermostatTerminal blockBareDraft dampermotorDraft damper ther-mostat110VblackwhiteFigure 36: Wiring for the c
*For a warming thermostat, 1should be the red wire and 2should be the black wire*For a cooling thermostat, 1should be the black wire and 2should be th
SAFETY FIRSTDO'S AND DON'TSIf this fireplace is not properly installed, a house fire may result. For your safety, follow the installationdir
Zone Thermostats(Heat Only)Zone 1JumperZone valves(8” NC)Zone 2Zone 3Zone 1Zone 2Zone 3Draft damperthermostatDraftdampermotorTransformerInternalblower
ONYX AP FIREPLACE OPTIONS FDHC4 Wall ThermostatFDHB5 Circulating Internal BlowerFDVO Gravity VentFDHB etFDHC6 Central HeatingFDKO Rock Retainer KitNot
REPLACEMENT PARTSNOT AVAILABLE N/APART OF ASSEMBLY P/ADESCRIPTION NEW CODE OLD CODE PRICEAsh pan plug Ash pan Top
REPLACEMENT PARTSNOT AVAILABLE N/APART OF ASSEMBLY P/ADESCRIPTION NEW CODE OLD CODE PRICEAsh pan plu
We recommend that our products be installed andserviced by professionals who are certified inthe U.S. by NFI (NationalFireplace Institute) or in Canad
ONYX AP - Limited Warranty30 Year Limited WarrantyAll RSF Woodburning Fireplaces models are warranted against defects in material and workmanship for
GENERAL SPECIFICATIONSTHE COMBUSTION CONTROL SYSTEMSince the door is sealed, all combustion air must come through a draft control. This control has a
CENTRALHEAT SYSTEM (option)You have the option to heat remote rooms in your home with the heat generated by your fireplace. If this option isinstalled
should be then placed in the bottom of the firebox. The baffle for the Onyx AP is in two pieces (11.6.N) and iseasily put into place at the top of the
GLASSIn a controlled combustion firebox temperatures are not always high enough to keep the glass clean. We havesupplied you with special ceramic gla
Figure 2: General assemblyRain capB-vent compo-nents for the gravi-ty system only.(or UltraBlack dou-ble wall connectormade by ICC)Ceiling clearance(m
3. Gold finish damage because of muriatic acid, plaster,cement, paint and harmful sprays or liquids, and sub-trade tool abrasion.STANDOFFSBefore you b